Rockwell Automation 440F Safedge Pressure Sensitive Safety Edge System User Manual
Page 10

3.2.6 Prick each of the copper wires with one of
the needles. Press the needle contacts of
the connector in the direction shown:
(wedge outwards), straight into the copper
wires.
3.2.7 CAUTION
The narrow side (wedge) of the connector
must show outwards.
3.2.8 Fold back the sealing lip of the cap;
a) Apply adhesive to shaded area of closing
cap as illustrated then affix to edge of
profile, applying pressure for 10 seconds
to ensure adhesion.
b) Apply adhesive to remainder of shaded area
and allow sealing lip to make contact with profile.
IMPORTANT: Spread the adhesive evenly over the
shaded area! Do not allow adhesive to enter inside
the profile.
5.3 APPLICATIONS
Z1
Z2
+
-
Brown
White
L
6K
RESISTOR
STOP
START
110/230V AC SUPPLY
110/230V AC Application with 2 contactors, contactor monitoring
and START/STOP circuit. (Shown with profile pressed)
MOMENTARY
PUSH BUTTON
EXTERNAL FUSE
+ve Z1 Z2 13 23 31
N
E -ve MC MC 14 24 32
SAFEDGE
PROFILE
SAFEDGE
CONTROL UNIT
K1
K1
K2
K2
K1
K2
(A1)
(A2)
L
6K
RESISTOR
K1
EXTERNAL FUSE
110/230V AC Application with 1 contactor.
(Shown with profile pressed).
+ve Z1 Z2 13 23 31
N
E -ve MC MC 14 24 32
SAFEDGE
PROFILE
SAFEDGE
CONTROL UNIT
(A2)
(A1)
18
9