3.2.9 To ensure complete seal apply more

adhesive on the Safedge Profile around
grommet/cable exit and sealing lip of the

closing cap.

3.2.10 Axial profile connector 440F-A0061S is used

for extensions and repairs (see steps 1, 2, 3,
6 and 7) for the 440F-E0110 series of profiles
only. For other types, use straight pin connectors.

3.3 CONTROL UNIT
3.3.1 TECHNICAL SPECIFICATION

440F-C251P Surface mount

440F-C251D DIN rail

Conformity:

prEN 1760-2, EN 954-1: CATEGORY 3

Power Supply - user select:

110/230V AC (50-60Hz) and 24V AC/DC +10% -15%

System response time:

13mS

Environmental protection:

IP65.

Enclosure IP40 DIN0470
Terminals IP20 DIN0470

Max. Safedge profile voltage:

12V DC (open circuit).

Nominal operating voltage:

4V (run condition).

Max. output fuse:

2A quick acting

5A quick acting

Impulse withstand voltage:

2500V.

Over voltage:

Category 2

Contamination level:

III

Min. switched current/voltage:

10mA/10V

Power consumption:

<6 VA

10

5.2 AUTOMATIC RESET MODE

1)

Turn the power on
a) Run “Green” LED illuminates.
b) Safety contacts close.
c) Auxiliary contacts open.
d) Contactors energise.

2)

Press the Profile
a) Run “Green” LED extinguishes.
b) Stop “Red” LED illuminates.
c) Safety contacts open.
d) Auxiliary contacts close.
e) Contactors de-energise.

3)

Release the Profile
a) System has returned to step 1a.

Comparative properties

Profiles

Profiles

440F-E0110N

440F-E0110S

440F-E0110R

440F-E0510S

440F-E1610N

440F-E1610S

440F-E0804S

440F-E0310S

440F-E0210S

Tensile strength (reinforced) MPa

26

20

Resilience (20

°C)

F

G

Low temperature flexibility

F

G

Resistance to sunlight

G

G

Resistance to heat ageing

G

G

Resistance to oxidation

F

G

Resistance to ozone

F

G

Resistance to H

2

O

G

G

Resistance to dilute acids

F

G

Resistance to concentrated acids

F

G

Resistance to oils & greases

G

P

Key:-

G = Good

F = Fair

P = Poor

17

440F-A0061S

Terminal block tightening torque rating 7 in/lbs,
suitable for wire sizes 16AWG.
Use 16AWG minimum.
Use Copper Conductors Only.
Temperature rating of field wiring shall not be
less than ambient.