6.0 MAINTENANCE AND SERVICE

6.1 FAULT FINDING GUIDE

Symptom

Probable Cause

Check

“Yellow” LED

Open circuit in profile or

Z1-Z2 Terminals are secure.

Illuminates.

connecting wiring.

Cable for breaks
Profile for damage.

No LED’s illuminate even if

Supply failure.

Voltage selector switch is set correctly.

Profile is pressed.

Supply fuse.
Supply voltage is present.

No LED’s illuminate unless

Failure to reset.

If using contactor monitoring, check

Profile is pressed and then

each contactor is functioning correctly.

the stop “Red” LED

MC-MC terminals are secure.

illuminates.

Link is in place or Reset button
functions correctly.

Unit appears to work

Blown fuse.

Output fuses.

correctly but there is no

Damaged or incorrect wiring.

All wiring for damage.

output.

Fault on Safedge causing

Movement on any internal relays.

the Outputs to fail safe

REPLACE CONTROLLER.

Machine does not stop if

Incorrect external connections

All wiring to contactors for mistakes.

Profile pressed.
Run “Green” LED goes off.
Machine does not stop if

DO NOT ALLOW THE USE OF THE MACHINE

Profile pressed.

REPLACE CONTROLLER.

Run “Green” LED stays on.

6.2 MAINTENANCE
This section should be read in full before any maintenance work is attempted.

Attention is drawn to regulations for planned preventative maintenance under E.U. Directive
89/655/EEC (Implemented in Great Britain as the Provision and Use of Work Equipment Regulations
1992).

During maintenance operations, disconnect the machine’s prime mover before working on the
Safedge system. Observe electrical safety precautions.

19

3.2.2 When using the closing cap 440F-A1302 with

sealing lip, the profile base has to be cut
back to a length of 12mm. The cut must
be made carefully to ensure that the profile
base is completely trimmed off, leaving a
flush surface.

3.2.3 The shaded areas must be roughened

with emery paper

3.2.4 The closing caps are moulded with 4

grommets, each with a rubber plug. When
fitting a resistor, leave the plugs intact. When
making a cable connection, select the
required cable exit and remove the plug from
the grommet with a hole punch.

3.2.5 Pull the connecting cable through the

hole.

12

8

Advertising