Protection

Short-Circuit Protection

Incorporated

Current limitation

Incorporated

Overload Protection

Incorporated

False Pulse Protection

Incorporated

Transient Noise Protection

Incorporated

Reverse Polarity Protection

Incorporated

Overvoltage protection

Incorporated

Thermal shutdown/restart

Incorporated

Electrical Life

10 x 10

6

Mode of Operation

Status indicators:

“Status/Diag” LED illuminates Green - Door/Guard closed, safety outputs active.

“Status/Diag” LED illuminates Red: - Door/Guard open, safety outputs off.

“Status/Diag” LED flashes Red or Green: - Unit failure. See Diagnostic section below.

Mounting Information

Do not over torque the mounting hardware.

Position the switch and actuator so they are aligned with each other.

Mount the switch and actuator to removable guard, door or gate.

Recommended fastener size - M6

Nut Torque Specification

Switch/Actuator: 2.20 N·M (19.5 in·lbs)

Minimum Distance Between Sensors

4

SensaGuard

TM

Installation Instructions