Diagnostic, Typical wiring diagram, 8sensaguard – Rockwell Automation 440N SensaGuard Integrated Latch Unique Coded Installation Instructions User Manual

Page 8: Installation instructions

Advertising
background image

8

SensaGuard

TM

Installation Instructions

Note: Refer to Technical Specifications for Certification information and ratings.

Note: Refer to Technical Specifications for Certification information and ratings.

Diagnostic

Unit Indicators (per IEC 60073)

State

Status

Troubleshooting

Off

Not Powered

NA

Status/Diag

Red

Not Safe, OSSD not active

NA

LED

Green

Safe, OSSD active

NA

Green flash

Power up test or OSSD

Check 24V DC or OSSD inputs

inputs not valid

(yellow and red wire)

Red Flash

1 Hz Flash OSSD Fault

OSSD fault —check OSSD

4 Hz Flash Recoverable /

outputs are not shorted to GND,

Non-recoverable Fault

24V DC or each other. Cycle power.

Typical Wiring Diagram

Description

Plastic

8-Pin Micro (M12)

Grey

Safety A

Red

Safety A+

Pink

Safety B

8-Pin Cordset

Yellow

Safety B+

889D-F8AB-*

White

Aux A

or cable version

Brown

24V DC+

Blue

0V

Green

N/A

* Replace symbol with 2 (2m), 5 (5m) or 10 (10m) for standard cable lengths.

2-24V DC+

1-Aux A

7-0V

6-Safety B

3-N/A

8-Safety A+

4-Safety B+

5-Safety A

Advertising