Page 17

vent the platform from unfolding
from the stowed position in the
event of platform drift. Due to
the “all-hydraulic” operation of
the dual-cylinder NL, hydraulic
ÁXLGH[SDQVLRQFRQWUDFWLRQRU
seepage may occur. Any of
these conditions may result in
platform drift (failure to hold the
platform in the folded or raised
position). Platform drift may
occur during lift shipment and/or
between extended periods of
non-lift use.

In the event that the platform
does not unfold when the
UNFOLD switch is pressed,
press the FOLD switch mo-
mentarily to disengage the
Lift-Tite

latches (platform drift

has occurred). Then, press the
UNFOLD switch to unfold the

Disengaged

Lift-Tite

Latch

Latch En-

gagement

Pin (Roller)

Operation Notes and Details

SODWIRUPWRÁRRUOHYHO VWDQGDUG
operation).

When manually operating a lift
equipped with Lift-Tite

latches,

insert the pump handle in the
pump and stroke until the plat-
form folds fully (stops). Then,

open the hand pump valve (turn
counterclockwise) to unfold the
platform. Folding the platform fully
ÀUVWZLOOHQVXUHWKDWWKH/LIW7LWH

latches will disengage properly
when the release valve is opened.
Manual Operating Instructions are
provided on pages 33-37.