Collecting and Reviewing Data Chapter 5

Follow these steps to take a spectrum measurement.

1.

Attach the transducer to the current location.

2.

From the Data Collection screen, press Enter.

The Route Manager Screen appears.

3.

Select the spectrum route you uploaded from the Emonitor software and
press Enter to start your measurement for the current point.

Figure 24 - Spectrum

Table 40 - Tasks Associated with Ranging the Measurement

If you

Then

Previously collected a magnitude measurement
for the point

the spectrum measurement starts automatically
after you press Enter to accept the magnitude
reading

Set Auto Advance to On in the Instrument
Configuration screen

the Dynamix 2500 data collector automatically
goes to the next point in the list after it finishes
collecting the spectrum

Set Auto Advance to Off

then the Signature Measurement screen appears

Set Fast Averaging to On in the Instrument
Configuration screen

the Dynamix collects the specified number of
averages before displaying the spectrum on the
screen

Set Fast Averaging to Off

the Dynamix displays the spectrum while
collecting the averages

View / add coded
and type-in notes

Leave without
storing data

Retake the
measurement

Set cursor frequency
as running speed

Point information:

Machine name
Point ID
Point description
Alarm condition

Cursor

Overall value

Current cursor frequency
and amplitude

Alarm indicators

Previous measurement
indicators

Percentage difference from
previous measurement