The firmware saves the parameters in EEPROM memory. Thus the
drive can be power cycled and, after power-up, will use the parameters
selected in the steps above.
When motion is required:
1. Close the switch between J1-26 and J1-20 to enable the drive.
2. Close the toggle switch between J1-26 and J1-32 to start Index 0.
3. Close the toggle switch between J1-26 and J1-33 to simulate reg-
istration.