Rockwell Automation 1441-DYN25-MRUC Run Up Coast Down Extension Module for the Dynamix 2500 User Manual
Page 16

16
Rockwell Automation Publication 1441-UM006A-EN-P - May 2011
Chapter 2
Run Up/Coast Down Extension Module
The application acquires a simultaneous noise or vibration signal and a
tachometer signal.
This example setup includes the following:
• Accelerometer attached to connector A of the Dynamix 2500 data
collector
• Optical tachometer signal connected to the POWER/USB/TRIGGER
cable
• Tripod for tachometer signal stability
• Speed reference trigger
• Small piece of reflective tape on the part of the shaft can serve as a reference
trigger or you can simply pass the laser over a notch in the shaft
This graphic illustrates a typical Run Up/Coast Down setup.
Figure 1 - Run Up/Coast Down Setup
The recorded data is saved in the form of a Microsoft .wav time waveform file.
You can analyze this file and viewed in a variety of different formats including:
• Bode Plot
• Nyquist Plot
• Table
• Waterfall
• Spectrogram
32147-M
Accelerometer
Tripod
Tachometer
Reflective Tape