Display the nyquist plot – Rockwell Automation 1441-DYN25-MRUC Run Up Coast Down Extension Module for the Dynamix 2500 User Manual

Page 27

Advertising
background image

Rockwell Automation Publication 1441-UM006A-EN-P - May 2011

27

Run Up/Coast Down Extension Module Chapter 2

Display the Nyquist Plot

When you are done setting up the plot parameters, you can process the data and
display the Nyquist plot by pressing F3 (Display) on the RUCD - Nyquist Setup
screen.

The display shows the selected orders as complex data with zero degrees along the
positive X-axis and 90 degrees along the positive Y-axis:

• To sequence through the traces, press the Up and Down arrows. The order

number of the current trace is displayed in the top left corner of the screen.
To move the cursor along the trace, press the Left and Right arrows.

• From the Nyquist plot you can display the data in a table or Bode plot,

press 0 (Shift) and F4 (Table).

See

Display the Table on page 30

for more information.

• To display the data in a Bode plot, press 0 (Shift) and then F1 (Bode).

See

Display the Bode Plot on page 24

for more information.

TIP

The larger the .wav file, the longer it takes to process the data
and display the plot.

Speed, magnitude, and Q
Factor at Cursor Location

Active Trace

Advertising