Bulletin 1500/1900 Isolation Switch Handle – Interlock Mechanism Replacement
1500-IN052C-EN-P – January 2007
Procedure for Operating Lever Replacement – STEP 5
Shoulder Pin
Retrofit Operating Lever
1) Lubricate the base of the Shoulder Pin with “O” Ring grease (Dow #55)
2) Assemble the Retrofit Operating Lever on the Shoulder Pin
3) Apply lubricant around the middle hole of the Retrofit Operating Lever