Rockwell Automation 1203 Serial Communications Module Series B User Manual
Page 39

4–5
Configuring and Interfacing
1203–5.5 September 1995
The following is the data table structure for PLC–2 style addressing:
Parameter
Number
PLC–2 Style Address
Decimal (Octal)
Description of Location’s Purpose
1 – 7039
512 + Parm #
(1000 to 16577)
Parameter value read
(16600 to 167770
Status of last parameter write
1 – 7039
7680 + Parm #
(17000 to 34577)
Parameter read full
(34600 to 34677)
Block transfer emulation area
(34700)
Logic command/status
(34701)
Reference/feedback
(34702)
Datalink A1
(34703)
Datalink A2
(34704)
Datalink B1
(34705)
Datalink B2
(34706)
Datalink C1
(34707)
Datalink C2
(34710)
Datalink D1
(34711)
Datalink D2
(34712)
#ENQs
(34713)
#NAKs
(34714)
Message TIMEOUT (mS)
(34715)
Application TIMEOUT (seconds)
(34716)
Adapter series number (2=B)
(34717)
Adapter firmware version (201=FRN2.01)
(34720)
Maximum node address (DH–485)
(34721 to 37677)
Reserved area for future expansion
(37700 to 37777)
System area
Note: The address locations shown in this table are not limited to
PLC–2 commands and may be used by any device that can generate
them.
"