Fault queue size, Plc block transfer emulation instruction data, Message operation – Rockwell Automation 1203 Serial Communications Module Series B User Manual
Page 66: Example

5–18
1203–5.5 September 1995
The Fault Queue Size function gets the number of fault entries
allowed in the fault queue.
PLC Block Transfer Emulation Instruction Data
PLC request instruction length: 3 words
Drive response instruction length: 4 words
Header
Word 1
PLC Decimal Value
1793
Message Structure
Header
Word 2
Data
Word 3
PLC Request
Header Word 1
Header Word 2
Header Word 3
Message Length
Message Length
PLC Decimal Value
1793 –– Message OK
–30975 –– Message Error
0
Drive Response
3
0
5
Data
Word 4
Fault Queue Size
Message Operation
The Fault Queue Size function reads back the size of the fault queue
available in the product. Each product may have a different number
of fault queue entries available for storage.
If an error has occurred, word 2 of the response returns a value of
–30975.
Example
In this example, a 1336 PLUS was used. This product has a fault
queue of four storage locations available to store faults. This value
is seen in word 4 of the response header message.
Data File Format
3
1793
0
* Example only – These values vary depending on parameters and products.
6
1793
0
4*
0
N10:0
N10:90
1
2
3
4
5
6
7
8
9
PLC request
Drive response
Fault Queue Size