1790D-T0V32 Input/Output Base Block Wiring Diagram

For sinking outputs, wire V dc 0 and V dc 1 to Field Power (+) 24V dc, and wire GND0 and
GND1 to Field Power (-) GND.

Connect the DeviceNet Cable

Follow these procedures to connect the DeviceNet cable to the base
block. The DeviceNet connector is not supplied with the base block.
You must purchase the connector separately. These are the types of
connectors you order directly from Rockwell Automation.

1799-DNETCON - 5-position open-style connector

1799-DNETSCON - 5-position open-style connector with
locking screws

1799-DNC5MMS - 5-position open-style to 12 mm (0.47 in.)
connector with locking screws

WARNING

If you connect or disconnect the communication cable with power applied to
this module or any device on the network, an electrical arc can occur. This
could cause an explosion in hazardous location installations.

Be sure that power is removed or the area is nonhazardous before proceeding

VDC0 OUT0 OUT2 OUT4 OUT6 OUT8 OUT10 OUT12 OUT14 24V OUT16 OUT18 OUT20 OUT22 OUT24 OUT26 OUT28 OUT30

OUT1 OUT3 OUT5 OUT7 OUT9 OUT11 OUT13 OUT15

OUT17 OUT19 OUT21 OUT23 OUT25 OUT27 OUT29 OUT31