Cable connector handling and maintenance, Supported drives – Rockwell Automation 1784-PM16SE 16 Axis PCI SERCOS interface Card Installation Instructions User Manual
Page 20
 
20 16 Axis PCI SERCOS interface Card
Publication 1784-IN041A-EN-P – June 2003
Cable Connector Handling and Maintenance
When cables are not in use, keep the ends covered with the dust covers that 
came with the cables. This helps to keep dust and small particles from 
blocking the optic path. Good system performance is dependent on clean 
port optics and cable ferrules to avoid obstructing the optical path. Clean 
compressed air is often sufficient to remove particles of dirt. You can also 
use methanol on a cotton swab. Recommended cleaners include: 
Supported Drives
The following Allen-Bradley drives are supported by the SERCOS interface 
motion card.
Alcohols
Aliphatics
Other
methyl
hexane
soap solution
isopropyl
heptane
naphtha
isobutyl
ATTENTION
!
The small junction size inherent in the design of these 
components increases the components’ susceptibility to 
damage from electrostatic discharge (ESD). It is advised 
that normal static precautions be taken in handling and 
assembly of these components to prevent damage and/
or degradation which can be induced by ESD.
Catalog Number
Description
1394C-SJT05-D
1394C 5KW SERCOS interface 460V drive
1394C-SJT10-D
1394C 10KW SERCOS interface 460V drive
1394C-SJT22-D
1394C 22KW SERCOS interface 460V drive
2094-AC05-M01
Kinetix 6000 3KW Power Supply/9A Drive, 230VAC
2094-AC09-M02
Kinetix 6000 6KW Power Supply/15A Drive, 230VAC
2094-AM01
Kinetix 6000 9A Drive, 230VAC