Communicate with Your ArmorBlock LP2 Module

This ArmorBlock module’s I/O is exchanged with the master through a
polled, change of state, or cyclic connection.

The module produces output data as follows:

Cyclic - allows configuration of the block as an I/O client. The block will
consume and produce its I/O cyclically at the rate configured.

Polled - a master initiates communication by sending its polled I/O
message to the module. The 16 output module consumes the message,
updates outputs, and producing a response. The response has output faults
and the status of the Auxiliary power.

Type of I/O Connections

Consumes

Produces

Cyclic

2 Bytes

1 Byte

Polled

2 Bytes

1 Byte

Change of State

2 Bytes

1 Byte

O-4

O-5

O-6

O-7

O-11

O-10

O-2

O-3

O-13

O-12

O-9

O-8