Figure 19 battery location, Red wire white wire battery – Rockwell Automation 1747-KE DH-485/RS-232C INTERFACE MODULE User Manual

Page 17

Advertising
background image

DH485/RS-232C Interface Module 17

Publication 1747-IN006B-EN-P - October 2005

To replace the lithium battery:

1. Remove power from the SLC 500 power supply.

2. Remove the module from the chassis by pressing the retainer clips at the top

and bottom of the module.

Figure 19 Battery Location

ATTENTION

Do not remove the module from the SLC 500 chassis until all
power is removed from the SLC 500 power supply.

IMPORTANT

If the top or bottom retainer clips are broken while removing the
module from the chassis, they can be easily replaced. Pry off any
broken clips from the bottom with a screwdriver, if necessary. Do
not twist off. Snap in the replacement clip. Order cat. no.
1746-R15 (two per package).

ATTENTION

Do not expose the module to surfaces or other areas that may
typically hold an electrostatic charge. Electrostatic charges can
alter or destroy memory.

SLC 500