8 SynchLink Bypass Switch Block

Publication 1751-IN003B-EN-P - September 2001

Wiring the Bypass Switch Block

To wire the bypass switch block and connect power:

1. Connect pre-terminated fiber optic cables as shown.

2. Pre-wire the removable connector plug as shown on the switch block label

or below.

3. Insert the removable connector plug into the mating connector receptacle on

the switch block.

ATTENTION

!

Do not look directly into the fiber ports or fiber cable. Light
levels may cause damage to eyesight. The bypass switch block
is a Class 1 LED product.

Connect

To

RxIN1

Upstream station transmitter

TxOUT1

Downstrean station receiver

RxIN2

Local station transmitter

TxOUT2

Local station receiver

Connect

To pin

+24V dc Power

4

24V dc Common

3

+24V dc Digital Input

2

24V dc Common Digital Input

1

IMPORTANT

Do not connect 24V dc Common to Chassis Ground.

31248-M

Pin 1 Pin 2 Pin 3 Pin 4

Power Supply and Digital
Input Connect (front view)

31249b-M

Pin 1 Pin 2

Pin 3

Pin 4

Connector receptacle on switch (front view)