DeviceNet Digital Base Terminal Block CompactBlock LDX I/O 5

Publication

1790-IN012B-EN-P - July 2008

North American Hazardous Location Approval

Before You Begin

Read this section about important CompactBlock I/O requirements.

Current functions of CompactBlock LDX I/O blocks require the
current, modular electronic data sheet (EDS) file for RSNetWorx for
DeviceNet software, version 8.0 or later. These files are are available
online at

http://www.ab.com/networks/eds/

.

EDS files for blocks with matching catalog numbers for both D-shell
and terminal block versions are the same. On the website and in
RSNetWorx for DeviceNet software, find the EDS file for both

The following information applies when
operating this equipment in hazardous
locations:

Informations sur l’utilisation de cet équipement
en environnements dangereux:

Products marked "CL I, DIV 2, GP A, B, C, D" are suitable
for use in Class I Division 2 Groups A, B, C, D,
Hazardous Locations and nonhazardous locations only.
Each product is supplied with markings on the rating
nameplate indicating the hazardous location
temperature code. When combining products within a
system, the most adverse temperature code (lowest "T"
number) may be used to help determine the overall
temperature code of the system. Combinations of
equipment in your system are subject to investigation
by the local Authority Having Jurisdiction at the time of
installation.

Les produits marqués “CL I, DIV 2, GP A, B, C, D” ne
conviennent qu’à une utilisation en environnements de Classe
I Division 2 Groupes A, B, C, D dangereux et non dangereux.
Chaque produit est livré avec des marquages sur sa plaque
d’identification qui indiquent le code de température pour les
environnements dangereux. Lorsque plusieurs produits sont
combinés dans un système, le code de température le plus
défavorable (code de température le plus faible) peut être
utilisé pour déterminer le code de température global du
système. Les combinaisons d’équipements dans le système
sont sujettes à inspection par les autorités locales qualifiées
au moment de l’installation.

WARNING

EXPLOSION HAZARD -

• Do not disconnect equipment

unless power has been removed
or the area is known to be
nonhazardous.

• Do not disconnect connections to

this equipment unless power has
been removed or the area is
known to be nonhazardous.
Secure any external connections
that mate to this equipment by
using screws, sliding latches,
threaded connectors, or other
means provided with this product.

• Substitution of components may

impair suitability for Class I,
Division 2.

• If this product contains batteries,

they must only be changed in an
area known to be nonhazardous.

AVERTISSEMENT

RISQUE D’EXPLOSION –

• Couper le courant ou s’assurer

que l’environnement est classé
non dangereux avant de
débrancher l'équipement.

• Couper le courant ou s'assurer

que l’environnement est classé
non dangereux avant de
débrancher les connecteurs. Fixer
tous les connecteurs externes
reliés à cet équipement à l'aide
de vis, loquets coulissants,
connecteurs filetés ou autres
moyens fournis avec ce produit.

• La substitution de composants

peut rendre cet équipement
inadapté à une utilisation en
environnement de Classe 1,
Division 2.

• S’assurer que l’environnement

est classé non dangereux avant
de changer les piles.