Rockwell Automation 1786-TPST2T ControlNet IP67 Tap and Cable Assembly Kit Installation Instructions User Manual

Page 11

Advertising
background image

ControlNet IP67 Tap and Cable Assembly Kit Installation Instructions 11

Publication 1786-IN017B-EN-P - May 2004

7. With the center pin in place, use the crimp tool to crimp the pin into place.

8. Slide the ControlNet connector onto the cable. Push the connector body on tight

until the center pin tip is flush with the inner ground ring.

9. Slide the crimp ferrule over the three outer shields and connector base until it meets

the shoulder on the connector.

10. Using the crimp tool, crimp the ferrule. Position the crimp tool on the ferrule as close

as possible to the connector base and ferrule meeting line. Press the tool tightly
around the ferrule until the crimp tool allows release.

TIP

The larger hexagonal crimping notch is for crimping the ferrule which
holds the connector to the cable.

TIP

Many network problems are due to improperly installed connectors.
You should have tight-fitting connectors on the ends of all your
cables. Pull the connector to verify that it is attached. If it is loose or
comes off, snip off the connector and install a new one. The
connector should withstand a minimum 60lbs pull force if properly
installed.

41903

The smaller hexagonal crimping notch is for crimping
the center pin onto the center connector.

Check for braid strands that could
cause a short to center conductor.

Advertising