106
• •
•
•
•
Regulate module
D
ESCRIPTION
The Regulate module provides discrete control for assigning the maximum rates of
regulators defined in the Tank module.
T
YPICAL
USES
Used to simulate such actions as the closing or opening of valves
P
ROMPTS
Priority
The priority of the flow operation when allocating limited input or
output to multiple flow operations occurring at a tank.
Allocation
Determines how the time and costs accrued during the flow operation
will be allocated to the entity.
Quantity Save Attribute
Attribute to save the quantity transferred by the entity.
Prompt
Description
Name
The module description.
Maximum Rate Assignments:
Regulator Type
Indicates how the regulator will be specified; defined as Regulator,
Regulator Set, Attribute, Expression.
Regulator Name
Name of the regulator.
Regulator Set Name
Name of the regulator set that contains the regulator.
Set Index
Index into the regulator set.
Attribute Name
Name of the attribute that stores the regulator name.
Expression
Expression that evaluates to the regulator name.
New Maximum Rate
The new maximum rate.
Units
Time units of new maximum rate.
Prompt