Installation and Startup
DL40 Plus Slave to PanelView RS-232 Printer Port
Connect the DL40 Plus Slave to a PanelView RS-232 printer port as 
shown below. The PanelView sends messages to the DL40 using its 
print messages function. You can also use the DTAM Plus 
programming cable (Catalog No. 2707-NC2) with a male-female pin 
adapter.
DL40 Plus Slave to 1771-DB BASIC Module
DL40 Plus Slave to 1746-BAS BASIC Module
DL40 Plus Slave
2
3
#
2
3
#
TXD
RXD
Signal Ground
TXD
RXD
Signal Ground
PanelView 900 Shown
DL40 Plus Slave
5
6
2
3
#
TXD (RS-232 Out)
RXD (RS-232 In)
Signal Ground
3
7
"
1
2
BASIC Module
RS-232 Peripheral Port
Shield
TXD
RXD
Signal Ground
RTS
CTS
DSR
DTR
RS-232 Port
DL40 Plus Slave
6
7
&
2
3
#
TXD (RS-232 Out)
RXD (RS-232 In)
Signal Ground
3
4
#
1
2
BASIC Module
RS-232 PRT1 Port
Shield
RXD
TXD
COM
DTR
CTS
DSR
DTR
RS-232 Port
No Connection