2-6 Installation

This diagram shows how to connect the ESRS to enable the device
from a source provided by your equipment and control the Enable
with volt free contacts.

Figure 2.5 ESRS Enabled via Volt Free Contacts – Power Supplied by Users
Equipment

External Power Supply

The following diagrams indicate how an external power supply
should be connected to the ESRS in cases where the encoder supply
in the target equipment has insufficient capacity to drive it. The

1

2

3

4

5

6

P1

P2

Users Volt Free
Contacts

5V to 24V DC