Drive specifications – Rockwell Automation 2092-DAx Ultra1500 Digital Servo Drive Quick Start User Manual

Page 13

Advertising
background image

Ultra1500 Digital Drives Quick Start 13

Publication 2092-QS001D-EN-P — July 2005

Drive Specifications

Drive 2092-DA1

2092-DA2

2092-DA3

2092-DA4

2092-DA5

Weight

0.9 kg (1.98 lbs)

1.2 kg (2.65 lbs)

2.1 kg (4.63 lbs)

Temperature

0° C to 50° C (32° F to 122° F)

Operating Shock,

and Vibration

15 G, Half Sine, 11 ms
5 – 500 Hz @ 2.5 G, 0.381 mm (0.015 in.) maximum displacement

Short Circuit Current Rating with
No Fuse Restrictions

Suitable for use on a circuit capable of delivering not more than 5000 rms
symmetrical amperes, 240 Volts maximum.

Short Circuit Current Rating with
Fuse Restrictions

Suitable for use on a circuit capable of delivering not more than 200,000 rms
symmetrical amperes, 240 Volts maximum, when protected by high interrupt
capacity, current limiting fuses UL198C (Class CC, G, J, L, R, T).

Motor Overload Protection

Utilizes solid state motor overload protection which operates:

• within 8 minutes at 200% overload.

• within 20 seconds at 600% overload

Symbols Used on Drive

Protective ground conductor terminal

Certification and Compliance

1

UL

®

listed to U.S. and Canadian safety standards (UL 508C File E145959)

CE and C-Tick marked for all applicable directives

Main Input Power

Nominal Input Voltage (V

rms)

2,3

200-240V, 1 phase, 50 or 60 Hz

200- 240V, 3 phase, 50 or 60 Hz

Input Current (A

rms

)

3.3A 5.5A 8.0A 11.0A 15.0A

Maximum Inrush Current (0-peak)

200A

Maximum Power Cycles/Minute

1 power cycle/2 minute interval

DC Bus Discharge Time

3 minutes after removal of main AC power

Control Input Power

Input Voltage (V

rms

)

2,3

200-240V, 1 phase, 50/60 Hz

Input Current (A

rms

)

2.0A

Maximum Inrush Current (0-peak)

75A

Motor Output

Continuous Output Current (0-peak)

1.4A 2.4A 4.7A 10.7A 16.4A

Intermittent Output Current (0-peak)

3.4A 7.2A 11.3A

24.8A

43.4A

Continuous Output Power @ 240V

ac

400W 650W 1000W 3000W 4000W

Power Dissipation

Maximum Power Dissipation

50W 50W 50W

+30W

4

100W+50W

4

150W+70W

4

1 Refer to www.ab.com/certification/ce/doc for more information.
2 Nominal values are listed. Absolute range is 180 to 264 V

rms

.

3 The AC input voltage between any two input power pins (L1, L2, L3, L1C, L2C, and CHASSIS) must not exceed this rating. This note also applies to the

CHASSIS ground connection, which implies that transformer secondaries must be grounded.

4 Maximum Power Dissipation includes dissipative power of drive plus the Continuous Shunt Power rating of the drive’s internal shunt.

Advertising