Ultra1500 Digital Drives Quick Start 7

Publication 2092-QS001D-EN-P — July 2005

Mating Connectors

Drive Displays

The 7-segment display provides operational information when the drive is functioning, or warning/
error messages when abnormalities are encountered.

Normal operational information consists of six characters that display data in three categories. The
categories consist of a Control Mode (characters 0 and 1), a Row Display (2), and Status (3 to 5).
Figure 6 depicts these categories and defines the information provided. Overtravel displays (see the
table following Figure 6) occur if the drive detects an overtravel condition.

Figure 6

Operational Drive Displays

Connector

Type

Wire Size

A-B Connector Kit or
Manufacturer P/N

Input Power

Single-row, spring
clamp connectors
with 7.5 mm spacing

2.5 - 0.8 mm

2

(12 - 28 AWG)

8 mm (0.3 in.) of wire
exposed

Wago 231-206/026-000

1

DC Bus and Shunt Power

Wago 231-204/026-000

1

Output (Motor) Power

Wago 231-203/026-000

1

CN1 - Input/Output

50-pin mini-D

0.2 mm

2

(24 - 30 AWG)

9101-1476

CN2 - Motor Feedback

20-pin mini-D

9101-1477

CN3 - Serial Interface

20-pin mini-D

1 Tool (Wago 231-131) for opening individual cage clamps on above power connectors is supplied.

Overtravel Display

Possible Cause

Action/Solution

Positive Overtravel

A Positive Overtravel condition is
detected.

Apply motion in a negative direction to back
off limit.

Negative Overtravel

A Negative Overtravel condition is
detected.

Apply motion in a positive direction to back
off limit.

Character: 0 1 2 3 4 5

rdy = Drive is disabled, but ready to be enabled
run = Drive is enabled and motor is under control

Status: Characters 3 through 5

Middle Row = Active if velocity exceeds Up To Speed parameter

Row Display: Character 2

Top Row = Inactive for any Current mode
Active if Velocity Mode. and Velocity Error is within the velocity window
Active if Follower Mode. and Position Error is within following error setting

Bottom Row = Active for hall startup motors once the commutation angle is set
Active for TL motor once the first index pulse occurs

C = Analog Current
d = Dual Current Command

Control Mode: Characters 0 and 1

F = Follower
S = Analog Speed
P = Preset Velocity