Configure the parameters – Rockwell Automation 1799-D10U10VZC Zone Control I/O Cards  User Manual

Page 14

Advertising
background image

14 Zone Control I/O Cards

Publication 1799-IN007D-EN-P - October 2005

Cyclic — the card produces and consumes its I/O cyclically at the rate configured by the
master on the DeviceNet network.

Polled — the master initiates communication by sending its polled I/O message to the card.
The card consumes the message, updates any outputs, and produces a response containing
the input data.

Change-of-state — a production occurs when an input changes. A heartbeat production
occurs if no input condition change occurs within the expected packet rate. This heartbeat
production tells the master that the card is ready to communicate. Consumption occurs when
data changes and the master produces new output data to the card.

Refer to the following table for the word and bit definitions:

Configure the Parameters

The Zone Control cards have 42 parameters that are configurable through a DeviceNet
configuration tool such as RSNetWorx for DeviceNet software. The DeviceNet
configuration tools require an Electronic Data Sheet (EDS) for the Zone Control cards to
configure the card’s parameters. Find the EDS file can be found at http://www.odva.org.

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Prod 0 Input 7

Input 6

Input 5

Input 4

Input 3

Input 2

Input 1

Input 0

Prod 1 RSVD

Logic Ena

RSVD

Input 9

Input 8

Prod 2 Output 7 Output 6

Output 5 Output 4 Output 3 Output 2 Output 1 Output 0

Prod 3

RSVD

Output 9 Output 8

Prod 4 NetOut 7 NetOut 6 NetOut 5 NetOut 4 NetOut 3 NetOut 2 NetOut 1 NetOut 0

Prod 5 CCV 7

CCV 6

CCV 5

CCV 4

CCV 3

CCV 2

CCV 1

CCV 0

Prod 6 CCV 15

CCV 14

CCV 13

CCV 12

CCV 11

CCV 10

CCV 9

CCV 8

Cons 0 Output 7 Output 6

Output 5 Output 4 Output 3 Output 2 Output 1 Output 0

Cons 1

RSVD

Output 9 Output 8

RSVD = Reserved, Logic Ena = DeviceLogix enabled, NetOut = Network Output,

CCV = Configuration Consistency Value,