Publication 2706-IN010C-MU-P

6 InView EtherNet/DeviceNet Module

Open the front of the sign case (on 2706-P7x) by turning the
latches to the left. Carefully let the front of the case drop
forward.

3. Feed the serial cable through the cable grip (shipped with

module).

4. Insert the serial wires through the right conduit opening on

either the top or the bottom of the InView display.

5. Mount the cable grip to the InView display housing. Tighten the

locknut finger-tight and rotate an additional 1/2 turn.

6. Connect the incoming serial wires to the TB1 terminal block.

POWER

LOAD

EARTH

GROUND

Quarter-turn latches

Front view, closed

Front view, open

EPROM unit (on
underside of board)

Controller board

2706-P72,
2706-P74

Power Line

Insert the serial wires
with the cable grip into
one of these conduit
openings.

TB1 Terminal Block for serial connection

Incoming
serial wires

TB1

(NC) 8
(NC) 7
(NC) 6
(NC) 5
(RS-232 RX) 4
(RS-232 TX) 3
(NC) 2
(GND) 1

Brown (Rxd)
Orange (Txd)

Blue (GND)

TB1 Terminal Block