Ups option – Rockwell Automation 7000L PowerFlex 7000 Medium Voltage AC Drive C Frame - Marine User Manual
Page 241

Component Definition and Maintenance 4-65
7000 ―C‖ Frame - Marine
7000L-UM302B-EN-P – June 2013
UPS Option
The PowerFlex 7000 ‗C‘ Frame drive has the option for internal and
external UPS power to keep the control power active within the drive
in the event of a control power loss. The following diagram shows
the current configuration of the internal UPS option:
Hold-up Capacitor
Holding Bracket
UPS
300W AC/DC Power Supply
Hold-up Capacitor
Holding Bracket
UPS
300W AC/DC Power Supply
Figure 4.51 – 300W AC/DC Power Supply
The UPS is installed in the incoming cabling section, below the LV
control section.
The UPS will keep control power to all the critical 120VAC loads
and an extra AC/DC Power Supply that feeds the DC/DC Power
Supply for powering all the drive control components. The main
drive cooling fan, and the AC/DC Power Supply that feeds the
IGDPS boards are not powered from this UPS.
The UPS is configured for the AS400 communication protocol, and
has several status signals that are fed back to the Customer Interface
Board to allow the control to respond to various conditions including
low batteries, loss of input power, UPS on bypass, etc.