46

6185 Economy Line Monitors

Publication 6185-UM003C-EN-P

Electrical

6185-H

6185-J and 6185-K

Line Voltage

90 to 264VAC

Line Frequency

47-70Hz or DC

Ground Leakage

1.0 uA max at 1.5KVDC

Power Consumption

30W max, 36 VA

42W max, 75 VA

Environmental
Panel Mount Option Rating

NEMA 4/4X/12 (built to IP65 or IP53 standards)

Operating Temperature

0C to 40C

Storage Temperature

-20C to 60C

Relative Humidity

10% to 80% non-condensing

Operating Altitude

Sea level to 10,000 ft (3048m)

Non-Operating Altitude

Sea level to 25,000 ft (7620m)

Operating Electrostatic
Discharge

8.0K VDC (IEC 801-2, level 3)

Non-Operating Electrostatic
Discharge

15.0K VDC

Operating Shock

10g (1/2 sine, 11 msec)

Non-Operating Shock

20g (1/2 sine, 11 msec)

Operating Vibration

0.006 in. p-p, 10-57 Hz sine,
1.0g peak, 57-640 Hz sine

Non-Operating Vibration

0.006 in. p-p, 10-57 Hz sine,
1.0g peak, 57-640 Hz sine

Physical

6185-H

6185-J and 6185-K

Front Panel Dimensions
(W x H x D)

17.25in. x 14.0in. x 0.3in.
(438mm x 355mm x 7mm)
(without rack adapter brackets)

19.0in x 15.7in x 0.3in

(483mm x 399mm x 7mm)

Rack Mount handles add 1.45” (37mm) to front
panel depth

Rear Chassis Dimensions
(from rear surface of front
panel to back) (W x H x D)

15.2in. x 12.3in. x 2.4in.
(386mm x 313mm x 61mm)

16.9in x 13.8in x 2.47in

(429mm x 351mm x 63mm)

Net Weight

15.6 lb (7.1 kg)

20.0 lb (9.1kg)

Shipping Weight

25.6 lb (11.6 kg)

30.0 lb (13.6kg)

Warranty
Standard

12 months

Optional

Extensions available