Ground your capacitor module to the subpanel, Additional resources – Rockwell Automation 2198-CAPMOD-1300 Kinetix 5500 Capacitor Module Installation Instructions User Manual

Page 7

Advertising
background image

Kinetix 5500 Capacitor Module 7

Publication 2198-IN004A-EN-P - October 2012

Ground Your Capacitor Module to the Subpanel

Ground Bulletin 2198 drives and 2198-CAPMOD-1300 capacitor modules to a bonded cabinet
ground bus with a braided ground strap or 4.0 mm

2

(12 AWG) copper wire.

Figure 5 - Connecting the Braided Ground Strap

Additional Resources

These documents contain additional information concerning related products from
Rockwell Automation.

You can view or download publications at

http://www.rockwellautomation.com/literature

. To

order paper copies of technical documentation, contact your local Allen-Bradley distributor or
Rockwell Automation sales representative.

Resource

Description

Kinetix 5500 Servo Drives User Manual, publication

2198-UM001

Provides information on installing, configuring, start up, and
troubleshooting your Kinetix 5500 servo drive system.

Kinetix 300 Shunt Resistor Installation Instructions,
publication

2097-IN002

Provides information on installing and wiring Kinetix 300
external shunt resistors.

Industrial Automation Wiring and Grounding Guidelines,
publication

1770-4.1

Provides general guidelines for installing a Rockwell
Automation industrial system.

Product Certifications website,

http://www.ab.com

Provides declarations of conformity, certificates, and other
certification details.

Braided Ground Straps

25.4 mm (1.0 in.) x 6.35 mm (0.25 in.)

Keep length as short as possible.

4

3

2

1

2198-CAPMOD-1300 Capacitor Module
(side view)

Item

Description

1

Ground screw (green) 2.0 N•m (17.5 lb-in), max

2

Braided ground strap (customer supplied)

3

Ground grid or power distribution ground

4

Bonded cabinet ground bus (customer supplied)

Advertising