Connect dc power – Rockwell Automation 6155R 200R VersaView Industrial Non-display Computers User Manual
Page 18

18 VersaView Industrial Non-display Computers
Publication 6155R-IN001I-EN-P - July 2007
Connect dc Power
The power supply on the VersaView 200R computer has a dc input terminal block
for connecting to a 9…36V dc power source.
Follow these steps to connect the VersaView 200R computer to a 9…36V dc power
source.
1. Turn off the main power switch or breaker.
2. Route the power wires from your dc power supply and connect the leads to
the dc input terminal block.
3. Tighten the screw terminals to provide a good connection.
4. Secure the terminal block connector to the computer by using the two side
screws.
5. Restore power.
ATTENTION
Connect the dc ground connection to a power source with an earth ground to
prevent electrical shock. Failure to follow this warning could result in electrical
shock.
The computer circuit should have its own disconnect. Use an uninterruptible
power source (UPS) to protect against unexpected power failure or power
surges.
Always shut down the operating system before removing power to minimize
performance degradation and operating system failures.
-V +V
-V
+V
9
…
36V dc
9
…
36V dc