Chapter 3
Using Application Generator

3 – 6

The

F4 – READ ALPHA

creates a field which will allow entry of all

displayable characters.

The

F5 – SPECIAL OPTIONS

which can be selected for reading fields

are:

Figure 3.5
AG Field Attributes Menu

AUTOEXIT:

When the operator has entered as many characters as are

in the field, then the read is completed. ‘Autoexit’ is added to the
Keyboard read statement.

DON’T CLEAR:

Prevents the field from being cleared on the first

character typed (see default). ‘No Clear’ is added to the Keyboard read
statement.

DEFAULT:

The previous value of the variable is shown instead of

displaying a blank field. ‘Default’ is added to the Keyboard read
statement.

ZERO FILL:

Numeric field is right justified with zeros. ‘Zerofill’ is

added to the Keyboard read statement.

PASSWORD:

***‘s are shown instead of the characters typed.

‘Secure’ is added to the Keyboard read statement.

If the

F6 – ACCEPT LASER INPUT ALSO

is selected then the laser is

included in the read statement.

Note: Range checks and other edit checks do not apply to this option.