L9 reading ranges – Rockwell Automation 2755-L7, -L9 Scanners User Manual

Page 10

Advertising
background image

Chapter 2
Product Description

2–3

Figure 2.3 illustrates the average reading ranges, relative to the symbol’s
minimum bar width, that you should expect when using an L9 scanner with
your
Catalog No. 2755–DM9 Decoder.

Figure 2.3
Average Scan Range vs. Minimum Bar Width for L9 Scanner

5

12.7

Inches

Centimeters

10

25.4

15

38.1

20

50.8

25

63.5

30

76.2

35

88.9

2755–L9SA

2755–L9RA

2755–L9SB

2755–L9RB

2755–L9SD

2755–L9RD

5

.13

35

.89

30

.76

25

.64

20

.51

15

.38

10

.25

Mils

Millimeters

Minimum Bar Width

① Scan Range will vary with symbol quality, pitch and skew. This application was based on no
more than 5

°

pitch and 30

°

skew, with full scan beam (Figure 5.3). Refer to Chapter 3, Installation

Considerations when reading labels with more than 20

°

pitch.

Scan Range (from face of scanner)

The following compares the minimum bar width to the scan range of each
catalog number.

Minimum Bar Width

Scan Range

Catalog Number

Mils

mm

Inches

Centimeters

Side

Scanning

Raster

Scanning

7.5

10
20

.19
.25
.51

6.5 – 8.5
6.0 – 9.0

5.0 – 11.0

16.5 – 21.6
15.2 – 22.9
12.7 – 27.9

2755–L9SA

2755–L9RA

11

20
25

.28
.51
.64

10 – 13.5

9 – 16

8.5 – 18

25.4 – 34.3
22.9 – 40.6
21.6 – 45.7

2755–L9SB

2755–L9RB

16
25
35

.41
.64
.89

10.5 – 21.5

9.0 – 25.5
7.5 – 30

26.7 – 54.6
22.9 – 64.8

19.1 – 76.2

2755–L9SD

2755–L9RD

② Scan range will vary with symbol quality. This application was based on no more than 5

°

pitch and 30

°

skew with

full scan beam (Figure 5.3). Refer to Chapter 3, Installation Considerations when reading labels with more than 20

°

pitch.
③ Scan range may be reduced when using low contrast labels.

L9 Reading Ranges

Advertising