4–6

When installing the Package Detector Assembly, we recommend you observe
the following guidelines:

Install the Package Detector Switch at an angle to the label to minimize
the light reflecting off the label.

Install the reflector so the Package Detector’s operating range is not
exceeded.

The Package Detector’s beam must be broken before the label is in
position.

Figure 4.4
Recommended Placement of Package Detector Switch and Reflector.

The laser beam must not strike the reflector, or you may get inaccurate reads

Scan Head

Package Detector

Switch

Reflector

Figure 4.5 specifies which pins on the Package Detector Port Connector
(Catalog No. 2755–NC9) are used.

Figure 4.5
Pins Used on Package Detector Connector

The package detector input is used to trigger the decoder to start decoding information. The package detect LED
on the Decoder will light when the package detect input is active.

Package

Detector Port

Package Detector Input

A

B

C

Common

+ 12V

Note: If you have programmed the decoder to turn the laser ON only upon a
package detect, the laser will be OFF until the package detector is triggered.
Refer to the User’s Manual for your decoder.