Chapter 4
Installation

4–5

A Flat Mounting Plate is also available. By attaching this plate to the bottom
of your scan head, you can position the swivel mounting ball close to the
base of the scan head. Make sure the Allen nut on the mounting ball is tight.

You may also use the Flat Mounting Plate when you want to mount the scan
head with brackets of your own design. Whenever possible, mount the
scanner on its wide side as shown on page 4–3. The dimensions are shown
in Figure 4.3.

Figure 4.3
Mounting Dimensions of the Flat Plate Inches (Centimeters)

0.204 (0.52)
& Countersunk

80

°

0.390 (0.99)
2 Places

.25
(0.64)

.31 (0.79)

.093 (0.24)

.25 (0.64)

6–32
UNC–2B
4 Places

.750
(1.91)

2.25 (5.71)

.38 (0.96)

3.50
(8.89)

3.000
(7.62)

2.812
(7.14)

1.625
(4.13)

1.500 (3.31)

Flat Mounting Plate with Mounting Screws Catalog No. 2755–NM3 Series B

Connect your equipment using the appropriate cables. Follow the
step–by–step procedure described below.

Step 1 With the power to the decoder OFF, connect your scanner to the port
labeled Scan Head on the back of the decoder.

Step 2 Connect the configuration terminal to the decoder’s Auxiliary port.

Step 3 The initial configuration should be done at this time, if it was not
done earlier (refer to the User’s Manual supplied with your decoder).

Step 4 If a host computer will be used, connect it to the port labeled Host on
your DM9 decoder.

Step 5 If output devices will be used, connect them to the decoder (refer to
the User’s Manual supplied with your decoder).

Step 6 If a package detector will be used, connect it to the small port on the
scan head.

Step 7 Refer to Chapter 5 for scanner operation.