Specifications

7–2

Optical

Light Source

Focused helium–neon (He–Ne) laser
(632.8nm)

Power

1.5 mW max.

Fixed Scan Rate

L7 350 scans/second,

±

5%

L9 – 800 scans/second,

±

5%

Scan sweep angle

L7 47

°

L9 27

°

Scan Range

L7 3.5” to 50” (8.89 cm to 127 cm) from
scan window. ①
L9 5” to 30” (12.7 cm to 76.2 cm) from
scan window ①

Depth of Field

L7 3.5” to 50” (8.89 cm to 127 cm) from
scan window ①
L9 5” to 30” (12.7 cm to 76.2 cm) from
scan window ①

Label Skew

L7 5

°

to 50

°

from normal ②

L9 5

°

to 50

°

from normal ②

Label Pitch

L7 5

°

to 45

°

from normal ②

L9 5

°

to 45

°

from normal ②

Package Detect

Min.

OFF–State Voltage

11 VDC

Max.

ON–State Voltage

2 VDC

Depending on the model selected

Depending on label quality