4 Kinetix 6000M Manual Brake Release Cable

Publication 2090-IN037B-EN-P - March 2012

Install the Cable

Follow these steps when installing a 2090-CBKS8-16AA03 manual brake release cable.

1. If an IPIM module is installed, verify power to the IPIM module is removed before

making any connections or disconnecting any components of the system.

2. Before beginning any cable bend, determine the recommended installation areas, and the

clearance required from the features shown in the diagram.

3. Keep cable bends within the bend radius listed in the Specifications on

page 6

.

This cable has a bend radius of twelve times the cable diameter.

4. Prevent the cable from flexing within 150 ±25 mm (6 ±1 in.) installation areas.
5. Tighten the M23 connector approximately 45° to fully seat the contacts and secure each

connection.

6. Attach each flying lead to the respective output on the external 24V DC power supply.

White to Ground

Black to 24V+

7. Apply 24V DC @ 650 mA to the cable terminals to release the spring set brake on the

IDM unit.

The the shaft can be manually rotated while the 24V is applied.

ATTENTION: Arcing or unexpected motion can occur if cables are connected or disconnected while
power is applied to the IDM system. Before working on an IDM system, disconnect power and wait
the full time interval as indicated in the warning on the IPIM module or verify the DC bus voltage at
the IPIM module measures less than 50V DC.

Failure to observe this precaution could result in severe bodily injury or loss of life, and damage to
the product will occur.

IMPORTANT

The internal O-ring is self-conforming and requires a short period between each
connect/disconnect cycle to expand to full size. Let the O-ring expand for at least 60 seconds
before reconnecting a hybrid cable.

Limited

Bend Zone

Female Plug

101.6 ±3
(4.0 ±0.12)

8 ±1
(0.3)

Black

White

Installation Area

300 ±25 (12 ±1.0.)

Drawing is not to scale. Overall cable length is 3 M (10 ft)

Dimensions are in mm and (in.).

Advertising