Kinetix 6000m cable routing diagram – Rockwell Automation 2090-CBKS8-16AA03 Kinetix 6000M Manual Brake Release Cable Installation Instructions User Manual

Page 5

Advertising
background image

Kinetix 6000M Manual Brake Release Cable 5

Publication 2090-IN037B-EN-P - March 2012

8. Remove the 24V DC power to apply the brake and prevent shaft rotation.

Kinetix 6000M Cable Routing Diagram

2090-CBKS8-16AA03 Cable Schematic and Connector Pinouts

2090-CBKS8-16AA03

Manual Brake Release Cable

MDF-SB1

xxx

Offline IDM Unit

Customer Supplied

24V DC @ 650 mA

The colored rings on the hybrid cable connector and the mating cable must match: red-to-red or green-to-green.

A
B
C
D
GND
1
2
3
4
5
6
7
8
9
10

GND

7

8

9 10

6

5

4

1

3

2

D

A

B

C

Female Connector

White

Black

Customer Supplied
24V DC @ 650 mA

+

-