Kinetix 6000m cable routing diagram – Rockwell Automation 2090-CBKS8-16AA03 Kinetix 6000M Manual Brake Release Cable Installation Instructions User Manual
Page 5
Advertising
Kinetix 6000M Manual Brake Release Cable 5
Publication 2090-IN037B-EN-P - March 2012
8. Remove the 24V DC power to apply the brake and prevent shaft rotation.
Kinetix 6000M Cable Routing Diagram
2090-CBKS8-16AA03 Cable Schematic and Connector Pinouts
2090-CBKS8-16AA03
Manual Brake Release Cable
MDF-SB1
xxx
Offline IDM Unit
Customer Supplied
24V DC @ 650 mA
The colored rings on the hybrid cable connector and the mating cable must match: red-to-red or green-to-green.
A
B
C
D
GND
1
2
3
4
5
6
7
8
9
10
GND
7
8
9 10
6
5
4
1
3
2
D
A
B
C
Female Connector
White
Black
Customer Supplied
24V DC @ 650 mA
+
-
Advertising