PowerFlex® 700S and 700H Drives, Frames 10…14, NEMA UL Type 12 / IP54 Replacement Door and Roof Filters

9. Insert the following new fiber filters, with the air flow direction arrow

pointing in toward the drive enclosure, into each of the door filter brackets.
See the illustration below for details.

10. Slide the filter brackets (with new filters) onto the screws on the inside of

the enclosure door and tighten the screws.

Frame

Voltage
Class

Drive Rating

Filter
Type

Dimensions (W x H x D)

Quantity

10

All

All

Fiber

450 x 330 x 45 mm (17.7 x 13 x 1.8 in.)

2

11

All

All

Fiber

650 x 330 x 45 mm (25.6 x 13 x 1.8 in.)

2

12

All

All

Fiber

450 x 330 x 45 mm (17.7 x 13 x 1.8 in.)

4

13

400V

1150 A

Fiber

450 x 330 x 45 mm (17.7 x 13 x 1.8 in.)

2

Fiber

650 x 330 x 45 mm (25.6 x 13 x 1.8 in.)

2

1300 A & 1450 A Fiber

650 x 330 x 45 mm (25.6 x 13 x 1.8 in.)

4

600V

All

Fiber

450 x 330 x 45 mm (17.7 x 13 x 1.8 in.)

2

Fiber

650 x 330 x 45 mm (25.6 x 13 x 1.8 in.)

2

14

400V

All

Fiber

450 x 330 x 45 mm (17.7 x 13 x 1.8 in.)

4

Fiber

650 x 330 x 45 mm (25.6 x 13 x 1.8 in.)

4

600V

1500 A

Fiber

650 x 330 x 45 mm (25.6 x 13 x 1.8 in.)

6

1900 A & 2250 A Fiber

450 x 330 x 45 mm (17.7 x 13 x 1.8 in.)

4

Fiber

650 x 330 x 45 mm (25.6 x 13 x 1.8 in.)

4

IMPORTANT

Verify the air flow direction on the fiber filters. You must install the
new filters with the air flow arrows pointing in the proper direction.

Air flow direction
through door filter

Air flow direction within
the drive enclosure

Air flow direction arrow
pointing in toward drive

Air flow direction
through door filter

Air flow direction within
the drive enclosure