background image

A-2

High Power SA3000 Power Modules

DC Bus Specifications

Pre-charge Time: 1 second

Discharge time (below 50V): less than 5 minutes

Pre-charge resistance/bus capacitance: 534A Unit: 7.6

/ 32.4 µF

972A Unit: 3.8

/ 64.8 µF

1457A Unit: 2.5

/ 97.2 µF

DC Bus Input Power

Nominal Maximum DC Voltage: 800 VDC

Input Voltage Range: 300 - 850 VDC

Overvoltage Trip: 925 VDC

Maximum DC Input Current: 534A Unit: 600A

972A Unit: 1000A
1457A Unit: 1500A

Use the following equation to calculate the approximate DC input current as a function
of the connected horsepower:

115 VAC Control Power

AC Input Voltage: 115 VAC, Single-phase (Critical and Non-critical supplies)

AC Input Frequency: 50/60 Hz

1

Maximum Symmetrical Short Circuit Current: 5 KA

1. Derate Power Module output current by 5% for 50 Hz blower motor operation.

115 VAC Input Power Ratings

115 VAC Power Supply

Part Number

534 Amp

Power Module

972 Amp

Power Module

1457 Amp

Power Module

850100-3R

1

1. May be replaced by 850100-3S 115VAC Power Supply Assembly.

10.6 A

16.5 A

21.6 A

850100-3S
(Non-Critical Power)

5.5 A

11.0 A

16.5 A

850100-3S
(Critical Power)

1.5 A (Min)

5.1 A (Max)

1.5 A (Min)

5.1 A (Max)

1.5 A (Min)

5.1 A (Max)

850100-3S (Critical
and Non-Critical Power)

10.6 A (Max)

16.5 A (Max)

21.6 A (Max)

DC Amps =

horsepower x 746

motor efficiency x inverter efficiency x bus voltage

Advertising