49

Light Curtain Multi-Function Control Module User Manual

Original instructions

Table 4 (* = a setting smaller or close to the total response time may influence the stability of the muting system)

Figure 69: Configuration window for “two sensor T-type w/enable signal” muting

Figure 70 shows the corresponding wiring diagram of the MSR42 control unit configured with “two sensor T-type w/enable signal” muting mode.

Parameter

Default Value

Max./Min. Values

Possible Settings

T(sens) [Figure 68]

4 s

Min.: 50 ms

Max.: 10 s

N x 0.05 s

T(mute) [Figure 68]

5 min

Min.: 0 ms

Max.: 10 days

(*)

T(msdel) [5.6.5]

50 ms

Min.: 0 ms

Max.: 2.55 s

N x 0.01 s

Muting lamp monitoring [5.6.2]

yes

yes/no

Mute dependant override [5.6.4]

yes

yes / no

T(mdo) [5.6.4]

5 s

Min.: 0

Max.: 20 min

N x 5 s

Mute disable signal [5.6.7]

no

yes / no

Micro 400 interruption monitoring [5.6.8]

no

yes / no

T(espe) [5.6.8]

5s

Min.: 0 s

Max.: 10 s

N x 0.05 s (*)