For Developers: Administering FactoryTalk Historian ActiveView

35

1. Open the Registry Editor.

2. Navigate to the CurrentVersion key:

HKEY_LOCAL_MACHINE\Software\PISystem\PI-
ActiveView\CurrentVersion

3. Right-click in the right-hand pane and select New/String Value.

4. Type PDITTL as the name of the value.

5. Right-click PDITTL, select Modify, and type the value in seconds.

6. Click OK.

This image shows an expiration value of 600 seconds.

FactoryTalk Historian ActiveView Setup

The Developer's Role

In FactoryTalk Historian ActiveView, the developer's role is to provide an
environment for the end user to view real-time data from the Historian
Server and other data.

In providing the software to end users, the developer must: