Installing the double pole circuit breaker – Rockwell Automation MinPak Plus DC Drive Double Pole CB Kit for NRG 14C210, 14C211, 14C212, 14C213 User Manual

Page 2

Advertising
background image

2

Double Pole Circuit Breaker Kit for Non-Regenerative MinPak Plus DC Drives

Installing the Double Pole Circuit Breaker

Refer to your drive instruction manual for help locating and identifying drive components. Refer to figure 1 for
wiring information.

To install the Double Pole Circuit Breaker in your non-regenerative MinPak Plus DC drive:

Step 1. Disconnect, lock out, and tag input power to the drive.

Step 2. Remove the drive cover and verify that no voltage is present at the drive’s AC input terminals, L1/181

and L2/182.

!

ATTENTION: Do not install modification kits with power applied to the drive. Disconnect, lock
out, and tag all sources of incoming AC power to the drive before attempting such installation.
Verify that no voltage is present at the drive’s AC input terminals, L1/181 and L2/182. Failure to
observe this precaution could result in severe bodily injury or loss of life.

ATTENTION: The user is responsible for conforming with all applicable local, national, and
international codes. Failure to observe this precaution could result in damage to, or destruction
of, the equipment.

Advertising