Rockwell Automation 20D PowerFlex 700H/700S AC Drives Frames 13 and 14 Main Fan Capacitor Rplcmnt. Kit User Manual
Page 12
Advertising

12
Rockwell Automation Publication PFLEX-IN027A-EN-P - July 2011
PowerFlex 700H and 700S AC Drives Frames 13 and 14 Main Fan Capacitor Replacement Kit
2. If you are replacing the fan capacitor on the V phase power structure of the
inverter unit, cut the cable tie that secures the ASIC board fiber-optic
cable bundle to the fan housing (if present) and remove the fiber-optic
bundle and rubber grommet from the support bracket in order to allow
room for the fan housing to be removed from the unit.
3. Disconnect the fan inverter power supply wires from the bottom of the
fuse holder.
PowerFlex 700S drive shown
Cut cable tie
and remove
wire bundle and
grommet from
bracket
V phase power structure
Disconnect
wires from
bottom of
fuse holder
Advertising