5

3. Secure the fan to the new short fan bracket with the screws retained

from step 2 above.

4. While pulling the isolation transformer’s wires inside the drive, at same

time install the new isolation transformer assembly from below the
drive into the left side of the main fan space (see

Figure 5

below).

Figure 5

5. Pull all extra wires to the side of the fan inverter case. Insert the rubber

bushing into the hole before installing the fan inverter board assembly
and the fuse rack (see

Figure 5

above). Tighten the M5 x 10 screws on

the bottom of the isolation transformer to hold it in place.

Install new
isolation
transformer
assembly

Install new rubber
bushing