PowerFlex® 700H/S Frame 9 Main Fan and Isolation Transformer Assembly Replacement

6. Make the isolation transformer and inverter board connections as

follows (see

Figure 6

below):

Install the “BLACK” female connector into the “FAN-BLACK”
terminal on the fan inverter board.

Install the “BLUE” female connector into the “FAN-BLUE” terminal
on the inverter board.

7. Connect the wires of the motor capacitor as follows (see

Figure 6

below):

Connect the “BROWN” male connector to the brown wire and the
“BLUE” male connector to the blue wire.

Figure 6

8. Connect the X2 control wire to the terminals of the motor capacitor and

re-install the fuse holder/capacitor bracket.

9. Cut the old isolation transformer wires, wrap the ends with electrical

tape and attach them to the frame with a cable tie.

10. Re-install the inverter board, the motor capacitor and the fuse holder/

capacitor bracket in reverse order. Also install the connector of the
small fan onto the fuse holder.

Important: Do not attempt to force the fan plate into the drive. This may

bend the fan.

Isolation
transformer and
inverter board
connections

Advertising