Rockwell Automation SA500 DC Bus Supply User Manual

Page 34

Advertising
background image

C-2

SA500 DC Bus Supply

Induction motor Iac current values are rated at 150% overload for 1 minute.

Table C.3 – Induction Motors

Model No.

HP

Max

Speed

RPM

Encl

Cont Iac

RMS

Amps

Cont Idc Amps

(Bus Supply

Requirement)

Max Iac

RMS

Amps

Max Idc Amps

(Bus Supply

Requirement)

Min DC

Bus

Supply

P14A5810

1

1757

TENV

3.0

3.8

4.5

5.7

1

1. Minimum bus supply: 615055-2R or 615055-2T. Output continuous current (Idc) = 50A.

P14A5804

1.5

1756

TENV

4.4

5.5

6.6

8.3

1

P14A5813

2

1764

TENV

5.8

7.3

8.7

11.0

1

P18A6111

3

1758

TENV

9.0

11.3

13.5

17.0

1

P18A6113

5

1737

TENV

14.4

18.2

21.6

27.2

1

P21L0212

5

1781

TENV

15.3

19.3

23.0

28.9

1

P21L0213

5

1180

TENV

14.8

18.7

22.2

28.0

1

P21L0214

5

880

TENV

14.8

18.7

22.2

28.0

1

P21L0215

7.5

1780

TENV

21.5

27.1

32.3

40.7

1

P21L0216

7.5

1177

TENV

20.6

26.0

30.9

39.0

1

P21L0217

7.5

866

TEAO

21.8

27.5

32.7

41.2

1

P21L0218

10

1779

TENV

27.8

35.1

41.7

52.6

1

P21L0219

10

1171

TEAO

27.3

34.4

41.0

51.6

1

P21L0220

10

868

TEAO

28.0

35.3

42.0

53.0

1

P21L0221

15

1768

TEAO

42.0

53.0

63.0

79.4

2

2. Minimum bus supply: 615055-2S or 615055-2V. Output continuous current (Idc) = 100A.

P21L0222

15

1172

TEAO

42.0

53.0

63.0

79.4

2

P21L0223

15

872

TEAO

41.1

51.8

61.7

77.7

2