Motor cables and accessory kits, Single motor cables, Sealing air accessory kit – Rockwell Automation VPS-B1653D-PJ12DF Kinetix VP Stainless-steel Servo Motor with 130...165 mm Frame Size Install User Manual

Page 18

Advertising
background image

18 Kinetix VP Stainless-steel Servo Motor with 130 mm and 165 mm Frame Size

Rockwell Automation Publication VPS-IN002A-EN-P - April 2013

Motor Cables and Accessory Kits

Accessories available from the factory include these items.

Single Motor Cables

Factory-manufactured single motor cables are available in standard cable lengths. They provide
the sealing needed to achieve environmental ratings and shield termination.

For a complete listing of available single motor cables, contact your nearest Rockwell
Automation sales office, or refer to the Kinetix Motion Accessories Specifications Technical
Data, publication

GMC-TD004

.

Sealing Air Accessory Kit

A sealing air pressure kit (catalog number MPS-AIR-PURGE) is available for field installation
on Bulletin VPS motors.

The kit provides a quick-release female air fitting. Positive air pressure applied to the motor
provides an additional level of protection against the ingress of foreign substances and moisture.

Sealing Air Accessory Kit Guidelines

You must supply these items with the sealing plug:

Plastic air tubing must be 4 mm (5/32 in.) OD Teflon FEP tubing.

Air supplied to the motor must not exceed 0.1 bar (1.45 psi).

Sealing Air Accessory Kit Installation

1. Remove the 5 mm (0.20 in.) sealing plug with a Phillips screwdriver.

Refer to the diagram

Mounting Dimension References, mm (in.) on page 10

for the

location of the sealing plug.

2. Inspect the air fitting and motor opening to verify that the surface area is undamaged,

and the contact area is clean.

3. Torque the air fitting to 1.1…1.2 N•m (9.7…10.6 lb•in).
4. Visually inspect the circumference of the connection for proper seating.

ATTENTION: Excessive air pressure or improper filtering of air can result in damage to the motor.

Air supplied to the motor must be clean, dry, and of instrument quality. Maximum air pressure is
0.1 bar (1.45 psi).

Failure to observe these safety procedures could result in personal injury or damage to equipment.

Advertising