Appendix b, Ppendix, Converter parameters – Rockwell Automation 1203-USB USB Converter (Same as DRIVES-UM001) Out of synch with AB version. User Manual
Page 43

Converter Parameters
B-1
A
PPENDIX
B
Converter Parameters
Appendix B provides information about the 1203-USB converter parameters.
Parameter List for DPI Drives
Topic
Page
Parameter List for DPI Drives
Parameter List for MDI Drives
No.
Name and Description
Details
01
DPI Port
Displays the port on the host drive to
which the converter is connected.
Default: 0
Minimum:0
Maximum:7
Type:Read Only
02
Reset Module
No action if set to “Ready.” Resets the
converter if set to “Reset Module.”
Restores the converter to its
factory-default settings if set to “Set
Defaults.” This parameter is a command. It
will be reset to “0 = Ready” after the
command has been performed.
Default:
0 = Ready
Values:
0 = Ready
1 = Reset Module
2 = Set Defaults
Type:
Read/Write
Reset Required:No
!
ATTENTION: Risk of injury or equipment damage exists. If
the converter is transmitting I/O that controls the drive
(indicated by a solid green diamond LED), the drive may fault
when you remove or reset the converter. Determine how your
drive will respond before removing or resetting a connected
converter.