Rockwell Automation 1203-USB USB Converter (Same as DRIVES-UM001) Out of synch with AB version. User Manual
Page 62

D-6
USB Converter User Manual
The AK-U0-RJ45-TB2P two-position terminal block connector (
used to conveniently daisy-chain the MDI Class drives from Drive 1, which is
connected to the 1203-USB converter. Two terminating resistors are also included
with terminal block connectors in the AK-U0-RJ45-TB2P kit.
shows a wiring diagram for using the AK-U0-RJ45-TB2P terminal block
connectors.
Accessing Drives on the RTU Master Network
Using one of the Reliance Electric drive software tools enables you to monitor,
configure, and control any of the drives on the RTU Master network. You can also
monitor and configure the 1203-USB converter.
Using V*S Utilities
Figure D.3 – AK-U0-RJ45-TB2P Terminal Block Connector
Figure D.4 – AK-U0-RJ45-TB2P Connector Wiring Diagram
To Slave Port on
Splitter Cable
(connected to Drive 1)
To Drive 2
To Drive 32
120
Ω
¼ Watt
Resistor
120
Ω
¼ Watt
Resistor
. . .
. . .